Rice Lake 882IS Intrinsically Safe Digital Weight Indicator
Designed for hazardous locations that are potentially explosive, the Rice Lake 882IS Intrinsically Safe Digital Weight Indicator is built to safely operate in these settings without sacrificing performance. With cFMus, ATEX and IECEx approvals, the 882IS is the industry’s choice for flammable and combustible applications such as fuel refineries, chemical plants, distilleries, textile manufacturing and more.
Safe, Accurate Weight Readings in Hazardous Locations – The intrinsically safe, auto-ranging power supply enables wiring to a single AC conduit line and seal from the safe area. An FM approved, rechargeable battery is also available for isolated power or movable applications. The Rice Lake 882IS Intrinsically Safe Digital Weight Indicator utilizes a backlit LCD display to maintain brilliant visibility for user-friendly operation, even in dimly lit areas. Its stainless steel enclosure provides superior protection from the elements.
Enhanced Connectivity – Expand flexibility with an optional safe area I/O Module, featuring a serial port, Ethernet TCP/IP and optional analog output or fieldbus cards for communication with printers, computers and other peripherals. A duplex fiber-optic port allows for electrically-isolated communication with the I/O Module. To complete the IS entity approved system, Rice Lake offers FM/ATEX-approved load cells and junction boxes that interface with the 882IS indicator
Manufacturer:
Rice Lake Weighing Systems
Types:
EX/Intrinsically Safe Instruments, EX/Intrinsically Safe Instruments, Extreme Environment and Wash Down Indicators
Industries:
Aerospace & Aviation, Chemical & Petrochemical, Food & Beverage, Manufacturing, Plastics & Polymers
Applications:
Cannabis Cultivation and Processing, Explosion Proof/Intrinsically Safe Weighing
Model | Description | Add to Quote |
195091 | Indicator,882IS 7.5 VDC SST Enclosure 5 Button Keypad With Standard Tilt Stand | Add to Quote |
185288 | Indicator,882IS 7.5 VDC SST Enclosure 5 Button Keypad With Battery Pack and Tilt Stand 115-230VAC charger NEMA 5-15(North American plug) | Add to Quote |
194231 | Indicator,882IS 7.5 VDC SST Enclosure 5 Button Keypad With Battery Pack and Tilt Stand 115-230VAC CEE 7/7 Continental Europe Charger | Add to Quote |
194232 | Indicator,882IS 7.5 VDC SST Enclosure 5 Button Keypad With Battery Pack and Tilt Stand 115-230VAC BS 1363 UK Charger | Add to Quote |
185290 | Indicator,882IS 7.5 VDC SST Encl. 5 Button Keypad W/AC Power Supply w/10ft(3m) PS cable 115-230VAC" | Add to Quote |
194235 | Indicator,882IS 7.5 VDC SST Enclosure 5 Button Keypad With A/C Power Supply. 115-230VAC with metric thread adapter (1/2NPT - M20) | Add to Quote |
195092 | Indicator,882IS Plus 7.5 VDC SST Enclosure Full Keypad With Standard Tilt Stand | Add to Quote |
185291 | Indicator,882IS Plus 7.5 VDC SST Enclosure Full Keypad With Battery Pack and Tilt Stand 115-230VAC charger NEMA 5-15(North American plug) | Add to Quote |
194233 | Indicator,882IS Plus 7.5 VDC SST Enclosure Full Keypad With Battery Pack and Tilt Stand. 115-230VAC CEE 7/7 Continental Europe Charger | Add to Quote |
194234 | Indicator,882IS Plus 7.5 VDC SST Enclosure Full Keypad With Battery Pack and Tilt Stand. 115-230VAC BS 1363 UK Charger | Add to Quote |
185293 | Indicator,882IS Plus 7.5 VDC SST Encl. 21 Keypad w/AC Power Supply w/10ft(3m) PS Cable 115-230VAC | Add to Quote |
194236 | Indicator,882IS Plus 7.5 VDC SST Enclosure Full Keypad With A/C Power Supply. 115-230VAC with metric thread adapter (1/2 NPT - M20) | Add to Quote |
- Battery option, IS6V2 VDC
- Battery charger, 6 VDC
- Power supply, 882IS mb-EPS-100-240-X2, dual output 6.8 VDC 200mA
- Cable, M12 power 22 in hazardous location (for battery version)
- Cable, M12 power 10 ft hazardous location
- Cable, M12 power 50 ft hazardous location
- Cable, M12 power 100 ft hazardous location
- Tilt stand, 882IS battery option
- Module, 882 smart I/O interface
Model | 882IS | 882IS Plus | |||||
185288 | 194235 | 195091 | 185291 | 185293 | 195092 | ||
Battery pack | Charger & Tilt Stand | Included | - | - | Included | - | - |
A/C power supply | - | Included | - | - | Included | - | |
Front Panel Control Switches | Zero, Gross/Net, Tare, Print, Units Conv, Start, Stop | Zero, Gross/Net, Tare, Print, Units Conv, Start, Stop, Full numeric keypad | |||||
Front Panel | Ten-button plus power button flat membrane panel | Ten-button plus power button flat membrane panel and full numric keys | |||||
Front Panel LED Annunciators | Center Zero, Gross, Net, Motion, lb, kg, oz, g | ||||||
Legal For Trade | NTEP CC 19-015 Class III/IIIL 10,000dMeasurement Canada | ||||||
Factory Mutual | FM entity approved for classes I, II, and III Divisions 1 and 2 Groups A, B, C, D, E, F, and G | ||||||
Load Cell Excitation: | 3.0 VDC at 87.5 O 4.6 VDC at 700 O | ||||||
Load Cell Current | 34 mA (4 x 350 & Omega load cells) or (8 x 700 & Omega load cells) | ||||||
Load Cell Cabling | 4 and 6-wire with remote sensing (recommended) | ||||||
Analog Signal Input Range | 0.6 mV/V - 4.0 mV/V | ||||||
Analog Signal Sensitivity | 0.2 µV/graduation minimum1.5 µV/graduation recommended | ||||||
Conversion Rate | 60 updates/second | ||||||
Resolution | 10,000 displayed graduations (NTEP Certified),100,000 expanded. The maximum number of allowed graduations will vary by application. | ||||||
Display Increments | 1, 2, 5 | ||||||
Decimal Point | Configurable with dead zeros | ||||||
Unit Switching | Configurable for 2 units of measurement with front panel operation with conversion for tare and setpoint values | ||||||
Motion Band | Configurable to ± 1 or ± 3 graduations, 1 second delay (or Off) | ||||||
Power Input | 5.8 - 7.9 VDC,100 - 175 mA Maximum power consumption 0.25 watts | ||||||
Operating Temperature | 14 F to 104 F (-10 C to 40 C) legal for trade | ||||||
Rating/Material | Stainless steel NEMA Type 4X/IP66 enclosure | ||||||
Optional Battery | Operating times: 4 x 350 O = 60 hrs 1 x 350 O =80-100 hrs Charging Times: 8-10 hrs for dead battery | ||||||
Weight | 6.1 lb (2.8 kg) | ||||||
Warranty | One-year limited warranty | ||||||
Approvals | NTEP CC 19-015 Class III/IIIL 10,000d c-UL Listed FM Entity Measurement Canada |
- Seven-digit, seven-segment LCD display with white LED backlight
- Stainless steel NEMA IP66 enclosure
- T4 temperature rating
- Front panel digital calibration
- Numeric keypad (882IS Plus only)
- Duplex fiber optic interface
- Power ON/OFF; battery save mode
- I/O module option: one serial port, optional analog outputs, optional fieldbus cards
- FM Entity Approved for use in hazardous locations per Rice Lake Weighing Systems control drawing file numbers 180948, 182301, and 186430