Minebea Intec Maxxis 5

Maxxis 5 side view

The Maxxis 5 combines accuracy, connectivity and functionality to provide a process controller unlike any other. Specifically designed to solve many of the problems faced by today’s manufacturers, it easily takes control of all modern automation processes.

As a multiple use device, the Maxxis 5 is pre-programmed to control a diverse range of complex applications. Minebea’s expert team of software engineers, in conjunction with industry specialists, have created software solutions that allow the unit to seamlessly integrate into any process. However, users who require it can utilize the easy to use IEC61131 programming language to implement their own unique functionalities.

The Maxxis 5 can be supplied with any of 6 standard applications pre-installed. These applications have been tested and perfected to ensure that you can integrate the unit directly upon delivery. However, for unique applications the Maxxis 5 can easily be re-programmed by your own technicians. Should you need any support with this task, our software specialists will be happy to help you.

Product formerly listed as Sartorius-Intec Maxxis 5.
Learn more about Minebea’s purchase of Sartorius’ industrial weighing assets



.
read more
  • Process Controller for the automated control of weighing processes with up to four scales
  • Wide range of opportunities for flexible integration such as option cards, housings, W&M certification and EX approvals
  • DAT, multilingual easy-operation interface , backup function, service reports, simulation
  • BASIC Application with weighing, check and remote terminal function
  • With an additional license: Internal alibi memory, OPC server, tilt correction
  • Supplied with Ethernet TCP | IP, Modbus TCP, RS232, RS485, USB, SD Card

PR5900/10 – A/D Converter
PR5900/04 – Interface Card Serial 2 x RS485 (incl. supply for IS Plattform)
PR5900/07 – Interface Card Analog 1x Input /1x Output 0/4-20 mA
PR5900/12 – Interface Card Digital 4x Input / 4x Output (activ)
PR5900/13 – Interface Card Digital 4x Input / 4x Output (passiv)
PR5900/17 – Control I/O Card 6-Inputs/8 Outputs
PR1721/51 – Interface Card Profibus DP
PR1721/54 – Interface Card DeviceNet
PR1721/55 – Interface Card CC-Link
PR1721/56 – Interface Card Profinet
PR1721/57 – Interface Card Ethernet/IP
PR5230/30 – Ethernet female connector RJ45, IP65
PR5230/31 – Ethernet cable with cable glance, 7M, RJ45 plug, Industrial Material
PR5900/41 – Serial Cable with cable glands (9 pin D-Sub plug male)
PR5900/42 – Serial Cable with cable glands (9 pin D-Sub plug female)
PR5900/43 – Serial Cable with cable glands (12 pin round plug male)
PR5900/44 – Serial Cable with cable glands (12 pin round plug female)
PR5900/60 – Maxxis 5 EX Remote Terminal, YPS0* Power Supply Required
PR5900/70 – Maxxis 5 EX Remote Terminal, Table Top Housing YPSC* Power Supply required
PR5900/82 – COUNT Application License
PR5900/81 – PHASE Application License
PR5900/83 – BATCHING Application License
PR5900/84 – TRUCK Application License
PR5900/86 – IBC – One Component Filling License
PR5900/87 – Tillt Correction License (Software Basic)
PR5900/91 – Alibi Memory License
PR5900/92 – OPC Server License
PR5900/93 – Special License “Batch Modes” for Programming

W1 / W2 – A/D Converter
WE1 – Weighing Point (A/D Converter) with intrinsically safe Load Cell supply
X3 / X4 – Disconnectable Load cell Connection
DE1 – Standard 4x Digital Input Passiv (external 24V supply needed)
DE2 – Standard 4x Digital Input Activ (internal 12V supply)
L0 – 110/ 240V AC Power Supply
L8 – 24V DC Power Supply
G1 – Maxxis 5 in Panel Housing
G2 – Maxxis 5 in Table Top Housing
G3 – Maxxis 5 in Table Top Housing with U-Bracket (turned front)
G4 – Maxxis 5 in Blackbox Housing (no Y2/Y3)
L12 – Backplate with cable glands
L13 – Backplate with EzEntry and cable glands (no Y2/Y3)
US – Cable for power supply for USA, Typ LAP31 (only with table top or U-Bracket housing)
EU – Cable for power supply with europlug, Typ CEE7 (only with table top or U-Bracket housing)
GB – Cable for power supply for GB, Typ 360 (only with table top or U-Bracket housing)
N31 – Cable fo power supply 24V without connector (open ended)(only with table top or U-Bracket housing)
B15 /B25 – Interface Card Serial 2 x RS485 (incl. supply for IS Plattform)
B16 / B26 – Interface Card Analog 1x Input /1x Output 0/4-20 mA
B17 / B27 – Interface Card Digital 4x Input / 4x Output (activ)
B18 / B28 – Interface Card Digital 4x Input / 4x Output (passiv)
Y2 – Zone 2/22 ATEX Approval
Y3 – FM Approval Class I,II,III Div. 2 (available Q3.2014)
F3 – Kit for W&M Approvals
C1 – Connection to Maxxis 5 Remote Terminal
CX1 – Connection to Maxxis 5 Ex Remote Terminal

ModelDescription 
PR5900/00Maxxis 5 Process Controller - Panel housing (G1), A/D converter(W1), 110/230V (L0),
Basic Application (H0), Digital Input passive (DE1)
PR5900/01Maxxis 5 Process Controller - Panel housing (G1), A/D converter(W1), 24V (L8), Basic
Application (H0) Digital Input passive (DE1)
PR5900/22Maxxis 5 Process Controller - Table top housing (G2), Rear plate cable glands (L12), A/D
converter (W1), 110/230V (L0), Basic Application (H0), Digital Input passive (DE1), Power
cable with USA plug(US)
PR5900/23Maxxis 5 Process Controller - Housing with bracket (G3), Rear plate cable glands (L12),
A/D converter(W1), 110/230V (L0), Basic Application (H0) Digital Input passive (DE1),
Power cable with USA plug(US)
PR5900/24Maxxis 5 Process Controller - Panel housing (G1), 110/230V (L0), Basic Application (H0),
Digital Input passive (DE1), Power cable with USA plug(US)
PR5900/27Maxxis 5 Process Controller - Housing with bracket (G3), Rear plate cable glands (L12),
A/D Converter (W1), 110/230V (L0), Basic Application (H0), FM Approval Class I,II,III Div.
2 (Y3), Digital Input passive (DE1), USA Power cable
PR5900/28Maxxis 5 Process Controller - Panel housing (G1), 24V (L8), Basic Application (H0), FM
Approval Class I,II,III Div. 2 (Y3), Digital Input passive (DE1), USA Power cable