Fairbanks FB2560 Scale Instrument
Fairbanks FB2560 Scale Instrument uses faster and more powerful processors to provide quick response time and a superior user experience. The processor went from 1.6GHz to 1.83GHz Quad Core. In addition, downtime is minimized with Intalogix technology, which allows the instrument to help diagnose load cell issues. Also, installation and calibration are streamlined in the FB2560 through the web interface. There are four configurations of this instrument: the Desktop Instrument; the NEMA Enclosure; the NEMA Panel Mount Instrument; the Rack Mount Instrument.
The Fairbanks FB2560 Scale Instrument now includes five USB ports. One is a USB 3.0 port, which can transfer data about 10 times faster than the older USB 2.0 standard. The operating system has been upgraded from Windows 8.1 to Windows 10, which will allow for extended operating system support for this family of instruments. The RAM was doubled to 4 GB to increase the speed of the user interface. Along with the new hardware, software enhancements include additional features to improve service and support.
The FB2560 Series Driver Assist Terminal (DAT) is designed to speed the vehicle weighing process and reduce associated operating costs. By allowing drivers to remain inside their vehicles, the FB2560 DAT also eliminates safety concerns and liabilities that can occur when drivers walk across scale platforms and traffic lanes. Axlematic applications allow for axle-by-axle weighing of vehicles on both full-length platform and short platform scales.
Note: You must select a load cell interface for each FB2560 ordered.
Manufacturer:
Fairbanks Scales
Types:
Advanced Indicators, Advanced Indicators, Indicators & Controllers, Truck Scale Accessories, Truck, Vehicle and Railroad Scales
Industries:
Aerospace & Aviation, Chemical & Petrochemical, Food & Beverage, Manufacturing, Medical & Pharmaceutical, Plastics & Polymers, Shipping & Freight, Transportation & Logistics
Applications:
Batching and Blending, Cannabis Cultivation and Processing, Scales with Data Acquisition & Export Ability, Shipping and Logistics, Tank, Hopper and Vessel Weighing
Model | Description | Details | Add to Quote |
36970 | FB2560 INSTRUMENT DESKTOP | Add to Quote | |
37040 | FB2560 SS NEMA 4X ENCLOSURE | Add to Quote | |
37042 | FB2560 NEMA 4X PANEL MOUNT INSTRUMENT | Add to Quote | |
37043 | FB2560 RACK MOUNT INSTRUMENT | Add to Quote | |
30916 | INTERNAL INTALOGIX INTERFACE | Factory Installed Allows FB2560 to interface to SSCs and DSSCs, and ISCs For up to 10 350Ω or 16 1000Ω load cells (max 2 scales) For more load cells, use 31281 External Intalogix communication device Only one (1) 30916 or 30944 per FB2560 | Add to Quote |
30944 | INTERNAL INTALOGIX INTERFACE | Field Installed Allows FB2560 to interface to SSCs and DSSCs, and ISCs For up to 10 350Ω or 16 1000Ω load cells (max 2 scales) For more load cells, use 31281 External Intalogix communication device Only one (1) 30916 or 30944 per FB2560 | Add to Quote |
33476 | EXTERNAL(SINGLE)INTALOGIX INTF | Mounts externally to FB2560 Allows FB2560 to interface to SSCs, DSSCs, and ISCs For up to 10 350Ω load cells or 16 1000Ω load cells (max 2 scales) Includes electronics, enclosure, and 8' FB2560-to-33476 cable | Add to Quote |
31281 | EXTERNAL (DUAL)INTALOGIX INTFC | Requires dual home run cables Mounts externally to FB2560 Allows FB2560 to interface to SSCs, DSSCs, and ISCs For up to 20 350Ω load cells or 32 1000Ω load cells (max 2 scales) Includes electronics, enclosure, and 8' FB2560-to-31281 cable | Add to Quote |
31079 | INTERNAL ANALOG LOADCELL INTRF | Allows FB2560 to interface to analog load cells and analog junction boxes Includes electronics and hardware For up to 8 350Ω cells or 16 1000Ω cells (max 1 scale) Controls only one (1) scale per 31079 Excitation voltage 5 VDC Does not feature Intalogix® Technology or load cell diagnostics | Add to Quote |
Specifications | |
Enclosure | Stainless steel NEMA 12 |
Processor | 1.8 GHz Quad Core |
Memory | 4 GB |
On-board Storage | 8 GB MINI PCIe |
Display | 6.0" x 3.5", 7.0" diagonal, 800 x 480 resolution TFT LCD with LED backlight Full color graphic with active matrix, NOT for outdoor use |
Touch Screen | Standard |
Camera Interface | Onscreen 2 cameras (switchable) |
Keypad | Oversized keys: 0-9, Decimal point, Enter, 5 Function keys, 8 Control keys |
Outputs | One (1) RJ-45 IEEE, 10/100/1000Base-T Ethernet TCP/IP port, Three (3) RS232C ports, One (1) RS232C / RS485* selectable, One (1) dedicated optically isolated 20mA |
USB Ports | Three (3) USB 2.0, One (1) USB 3.0, and one (1) port for the keyboard |
Power Requirements | 100 240 VAC at 47 63 Hz |
Clock | Real time clock, Day of the week 12-hour AM/PM, Date (month/day/year) |
Multiple Scales | One instrument can run up to 8 scales, maximum of 32 load cells per instrument |
Displayed Characters | 3/8" Tall |
Display resolution | 10,000 divisions commercial 50,000 divisions non-commercial |
Capacity | Programmable to 999,999 |
Displayed Units | 7 Primary and 7 Secondary |
Calibration and Configuration | Parameters can be configured locally at instrument, or remotely by means of an Ethernet connection and standard browser |
Product Files | 250,000 |
Customer Files | 250,000 |
Stored Tares | 500,000 |
Reports | Seven (7) on-board reports |
Transaction Records | 1,000,000 (10,000 with 2 images) |
Humidity | 0 to 90% |
Accuracy | Class III/IIIL |
- Large full-color display
- Touch screen operation
- Multiple/expandable serial ports
- Ethernet
- Programmable prompts
- Built-in reporting functions
- IP Camera interface
- Integrated web server
- SQL database
- One (1) Accessory Expansion Card 30917
- Shutdown Management System
- You must select a load cell interface for each FB2560 ordered.
- External keyboard (25498 or 31036) not included.
- External keyboard required for alpha character data entry.
- Cameras not provided by Fairbanks are not supported.
- Adding more than two (2) accessory cards to an FB2560 requires an additional 30917 Accessory Expansion Card.
- Accessories are field-installed unless otherwise noted.
- FB2560 Scale Instrument Literature
- FB2550 Scale Instrument Brochure
- FB SOLAS Compliance
- Active Analog Option
- Analog Load Cell Interface
- Loop Detectors
- NEMA Versions
- Networking Functions
- Enhancements
- On Scale Alarm
- Additional Enhancements
- Additional Enhancements 2
- FB 2550 Information
- Software Release
- Software Release 2
- Scale Summing
- Shutdown Management System
- Ticket Formatting
- Transcore RFID Reader Interface