Minebea Intec PR 6211 Compact Compression Load Cell Features

Posted on November 29, 2016
  • Easy to install in limited space
  • Easy corner adjustment by matched D1 load cell outputs
  • Full stainless steel construction
  • Wide temperature range
  • Resistant against vibrations
  • Hermetically sealed, IP68 (depth of 1.5 m for 10,000 hrs.), IP69K
  • Ex-version available (500kg…10t)
  • W&M approval (acc. OIML R 60)
  • Integrated overload protection for up to300kg capacity
  • Load cell construction – Hermetically sealed, welded stainless steel construction, filled with polyurethane and inert gas.
  • Material – 1.4542 (DIN 17440) acc. to S604, S622 (B.S.)
  • Protection – IP 68, IEC 529 (equivalent to NEMA 6). The load cell can be submerged in water to a depth of 1.5m for 10,000 hours, IP 69K rugged, flexible, screened; TPE thermoplastic Elastomere; Sheath: grey; PR 6211/..D1E, Colour: blue; PR 6211 LT: PFA Thermoplastic, Colour: red; Diameter: 5mm, wires 4 x 0,35mm2; PR6211/30… 300kg: 3mm, 4 x 0,13mm2; Length : 5m; PR6211/30… 300kg: 3m
  • Bending radius – Fixed installation: ≥ 50mm; Flexible installation: ≥ 150mm
  • Certificate of conformity – Valid for: PR 6211/… D1E (500kg… 10t); Feature: II 1G EEx ia IIC T6, II 1D IP65 85°C; Registration number: PTB 02 ATEX 2059, TÜV 03 ATEX 2301x

This article is linked to the following:


Categories:Features


Manufacturer: