Certificate Retrieval
Contact⏷
Request a QuoteRequest a Virtual AppointmentRequest CalibrationRequest ServiceProvide Feedback
About⏷
AccreditationNewsRecognitionsHistoryTestimonialsGiving BackOur EmployeesCareersPurchasing TermsPrivacy
800-225-8181
Nicol Scales
Products ⏷
Scales &
Weighing
Process Control
& Tank Weighing
Force
Measurement
Materials
Testing
Torque MeasurementDimension, Speed and PressureLab
Equipment
Dimensional
Tools
Rentals, Used
& In-Stock
Products by
Industry
Products by
Application
Products by
Manufacturer
Calibration ⏷
What We CalibrateSafetyReasons to CalibrateQuality PolicyEasyCal ProgramCalibration LabsOnline CertificateCalibration CapabilitiesForce Gauge Calibration
Service ⏷
Repair CapabilitiesFlexible Service OfferingsTraining & InstallationSafetyCustom SolutionsProof and Load TestingManufacturer Service CentersRental Equipment
Library ⏷
Application StoriesWhite PapersVideosWebinarsTesting TypesInternational Testing StandardsTesting by MaterialGlossary
Search

  1. Products
  2. Sartorius
Sartorius Cubis Micro Balances

Cubis Micro
Add to Quote
Request a Virtual AppointmentRequest CalibrationRequest Service
Please note that this is an obsolete product.

The Cubis is obsolete and has been replaced by the Cubis II.

Ultramicro | micro balances designed for the smallest samples and high resolutions of up to 0.0001 mg. Sartorius Cubis Micro Balances provides maximum weighing performance, APC functions for reliability in regulated areas, security and full network capability. Equipped with a touch screen, it is also suitable for customized workflows (Q-Apps). For use with heavy tare containers, Sartorius offers the ME and Competence series. Special microbalance versions are available in the Cubis Micro Balance range for filter weighing.

Manufacturer:
Sartorius

Obsolete
Models
ModelWeight CapacityResolutionAdd to Quote
MSU3.6P-000-DM1.1/2.1/3.1g1.0/2.0/5.0µg
Add to Quote
MSA3.6P-000-DM1.1/2.1/3.1g1.0/2.0/5.0µg
Add to Quote
MSE3.6P-000-DM1.1/2.1/3.1g1.0/2.0/5.0µg
Add to Quote
MSA3.6P0TRDM1.1/2.1/3.1g0.01g
Add to Quote
MSU2.7S-000-DM2.1g0.1µg
Add to Quote
MSA2.7S0TRDF2.1g0.1µg
Add to Quote
MSA2.7S0TRDM2.1g0.1µg
Add to Quote
MSA2.7S-000-DF2.1g0.1µg
Add to Quote
MSE2.7S-000-DF2.1g0.1µg
Add to Quote
MSU2.7S-000-DF2.1g0.1µg
Add to Quote
MSA2.7S-000-DM2.1g0.01g
Add to Quote
MSE2.7S-000-DM2.1g0.001g
Add to Quote
MSA6.6S0TRDM6.1g1.0µg
Add to Quote
MSU6.6S-000-DF6.1g1.0µg
Add to Quote
MSU6.6S-000-DM6.1g1.0µg
Add to Quote
MSA6.6S-000-DF6.1g0.001g
Add to Quote
MSA6.6S-000-DM6.1g0.001g
Add to Quote
MSE6.6S-000-DF6.1g0.001g
Add to Quote
MSE6.6S-000-DM6.1g0.001g
Add to Quote
Information
Sartorius Cubis Micro Balances
Specifications
Linearity0.004mg
Corner load(test load [g])0.004
Sensitivity drift between +10 to +301 ppm/K
Typical stabilization time<
5 sec
Typical measurement time<
8 sec
Display result0.1 - 0.4
OperationTouch screen keys for central basic functions
Adaptation of the display and control unitTiltable display
removable display and control unit
Standard data interfacesUSB (integrated into weighing module)
Various data protocols available (can also be connected to software designed for external manufacturers)
RS-232C accessory interface25-pin (integrated into weighing module)
SD card readerIntegrated as standard into display and control unit
ApplicationsUnit conversion
SQmin function for minimum initial weight according to USP
isoCAL automatic calibration | adjustment function
individual identifiers
density determination
statistics
calculations
averaging
formulation
weighing in percent
time-controlled functions
totalizing
DKD measurement uncertainty
second tare memory
counting
checkweighing
alibi memory
audit trail
Power supply100240 V~, 15 %/+10 %, 5060 Hz, 1.0 A
Input voltage15 VDC, ± 5 %
Power consumption7W (max.)
Ambient temperatureOperation +5 to +40C
Highest relative humidity80 % for temperatures up to 31C, decreasing linearly to 50 % relative humidity for 40C
Safety of electrical equipmentAccording to EN 61010-1:2001: Safety requirements for electrical equipment for measurement, control, and laboratory use Part 1: General requirements
Electromagnetic compatibilityAccording to EN 61326-1:2006: Electrical equipment for measurement, control, and laboratory use EMCrequirements Part 1: General requirements
Defined immunity to interferenceSuitable for use in industrial areas
Interference emissionClass B (suitable for use in residential areas and areas that are connected to a low voltage network that also supplies residential buildings).
Resources
  • Cubis Brochure
 
This chapter states the requirements for balances used for materials that must be accurately weighed (see General Notices, 8.20). Unless otherwise specified, when substances must be “accurately weighed”, the weighing shall be performed using a balance that is calibrated over the operating range and meets the requirements defined for repeatability and accuracy. For balances used for other applications, the balance repeatability and accuracy should be commensurate with the requirements for its use. For discussion of the theoretical basis of these requirements, see general information chapter Weighing on an Analytical Balance 1251, which may be a helpful – but not mandatory – resource. Read more about Chapter 41 here.
  • Cubis Micro Balances Manual
Related Products
Sartorius Cubis Micro Balances ModelsInformationResourcesRelated Products
Nicol Scales
HOME CERT. RETRIEVAL CONTACT US ABOUT US ACCREDITATION
Four locations to serve you better! Dallas, Fort Worth, Houston, and San Antonio / Austin,
Copyright ©2026 NicolScales
 
×

Contact Us

Contact Us (2024)
×

Get a Quote

Get a Quote
You can submit the request now, or return to the site to add more products Add More Products Sending
×

Service Request

Please allow 1 business day for a representative from Nicol Scales & Measurement to contact you. If your need is urgent, or if it’s after normal business hours, please call our local branch for service.

  • (800) 225-8181 will call the branch nearest you.
  • Austin - (512) 312-9220
  • Dallas – (214) 428-8181
  • Houston – (281) 445-9021
  • Fort Worth – (817) 332-8116

Request a Service Call
Sending
×

Request a Calibration

Request for Calibration

Maximum file size: 268.44MB

You can upload your equipment list here using a standard spreadsheet or document format
Sending
×

Request a Virtual Appoiment

Virtual Appointment Request
×

Provide Feedback

Customer Feedback

Please rate our performance in each area

Sending